PRODUCT TYPE ABBREVIATIONS

 
Li
: strand conductor construction
F : finest-strand construction
Y : plastic based on PVC
2Y : plastic based on PE
9Y : plastic based on PP
YW : national abbreviation for temperature-resistant plastic based on PVC
11Y : Kunststoff auf PUR-Basis
12Y : plastic based on TPE-E
30Y : thermoplasic natural rubber
31Y : temperature-resistant thermoplasic elastomer
32Y : special temperature-resistant thermoplasic elastomer
X : radial distributed PVC
2X : cross-linked polyehylene
11X : radial distributed PUR
SK : suitable for dragchains
FRNC : flame retardant and halogen-free wire
-J : including green-yellow ground wire
-O : without green-yellow ground wire
-B : coloured wires
-Z : number print
-C : screening meshwork

general harmonised abbreviations:

H
: harmonised wires
S : special wires
03 : nominal voltage Uo/U 300/300 V
05 : nominal voltage Uo/U 300/500 V
07   nominal voltage Uo/U 450/470 V
V : PVC based wire insulation
V : PVC based sheath material
V2 : harmonised abbreviation for temperature-resistant PVC (+ 90° C)
-F : finely-wired construction of bunched conductors according to DIN VDE 0281
3G : twisted wire with three wires and green-yellow ground wire
0,75 : 0,75 mm² conductor cross section

 

>>

 TYPE ABBREVIATION OF AUTOMOTIVE WIRES

 
wire type
FL
: automotive wire, low voltage
FZL : automotive wire, high voltage, (ignition line)
 
application of used insulation and sheath material
Y
: PVC, polyvinyl chloride
 
type of used shielding material
B
: foil shield with ground wire
D : copper-based single wire shield
C   copper screen
   
non-extruded sheaths
G
: fibre glass mesh
T : textile weave
 
special construction features
R
: 4 reduced insulation thickness according to DIN ISO 6722, Part 4
U : ultra reduced insulation thickness
S : insulation thickness bigger than according to DIN ISO 6722, Part 3
F : non-seperable flat wire
Z : multiple core, non-separable wire
M : other conductor materials than E-Cu or resistance alloies
W : resistance conductor
 
number of wires and conductor cross section
0,5
: conductor cross section 0,5 mm²
0,5 sn : conductor cross section 0,5 mm², tinned
3 x 0,5 : three wires with conductor cross section 0,5 mm² each
W/km : on resistance conductors information in Ohm/km
 
examples:
FLRY 2,50 mm² verz : FL = automotive wire
R = with reduced insulation thickness
Y = PVC insulation
2,50 mm² verz = conductor cross section 2,50 mm² tinned
 
FL11Y 16,00 mm² blk : FL = automotive wire
11Y = PUR sheath
16,00 mm² blk = conductor cross section 16,00 mm² bare
 
FLRYY 3 x 0,25 mm² blk : FL = automotive wire
R = with reduced insulation thickness
Y = wire insulation PVC based
Y = sheath insulation PVC based
3 x 0,25 mm² blk = three single wires with cross conductor section 0,25 mm² each, bare